This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
-
Technical Information (TI)
Proline Promag 10L Technical Information
Electromagnetic flowmeter
The flowmeter with a weight-optimized sensor and highly
cost-effectivenessEN Select other language 27/11/201728/04/201601/02/201501/12/201101/07/2011Language:
English
Version:
27/11/2017
File size:
3 MB
File name:
TI00100DEN_1917.pdf
-
-
-
Operating Instruction (BA)
Proline Promag 10 HART Operating Instructions
Electromagnetic flowmeter
EN Select other language 27/11/201713/03/201709/02/201601/02/201501/04/2014Language:
English
Version:
27/11/2017
File size:
8.2 MB
File name:
BA00082DEN_1917.pdf
-
-
-
Short Instruction (KA)
Proline Promag 10 Brief Operating Instructions
Electromagnetic flowmeter
EN Select other language 27/11/201713/03/201704/04/201609/09/201501/02/2015Language:
English
Version:
27/11/2017
File size:
1008.4 KB
File name:
KA00032DEN_2017.pdf
-
-
-
Installation Instructions (EA)
EA Replacing cover and O-ring
Proline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN Select other language 15/10/202401/10/201828/06/2012Language:
English
Version:
15/10/2024
File size:
797.3 KB
File name:
EA00098DA2_1624-00.pdf
-
-
-
Installation Instructions (EA)
Repair kit cover remote version Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65EN Select other language 01/10/201813/11/201418/04/2014Language:
English
Version:
01/10/2018
File size:
216.9 KB
File name:
EA01108DA2_0318.pdf
-
-
-
Installation Instructions (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN Select other language 01/03/201828/11/201325/04/2013Language:
English
Version:
01/03/2018
File size:
139.5 KB
File name:
EA01051DA2_0318.pdf
-
-
-
Installation Instructions (EA)
Replacing transmitter parts Installation Instructions
Promag 10, Prosonic Flow 91 W
EN Select other language 01/04/201917/11/2011Language:
English
Version:
01/04/2019
File size:
558.9 KB
File name:
EA00040DA2_1419.pdf
-
-
-
Installation Instructions (EA)
Replacing the transmitter Installation Instructions
Promag 10, 23, 50, 53, 55
EN Select other language 01/04/201902/03/2010Language:
English
Version:
01/04/2019
File size:
1 MB
File name:
EA00082DA2_1119.pdf
-
-
-
Installation Instructions (EA)
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
EN Select other language 09/10/202001/03/201815/07/2014Language:
English
Version:
09/10/2020
File size:
698.2 KB
File name:
EA00070DA2_1520.pdf
-
-
-
Installation Instructions (EA)
Replacing Sensor parts remote version Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, Cubemass 8CN,
CNGmass 8DFEN Select other language 01/04/201928/06/2012Language:
English
Version:
01/04/2019
File size:
313.4 KB
File name:
EA00038DA2_1419.pdf
-
-
-
Installation Instructions (EA)
Interface parts Installation Instructions
Promag 10, 23, 50, 51, 53, 55, 400, 800
EN Select other language 01/05/201728/06/2012Language:
English
Version:
01/05/2017
File size:
1.1 MB
File name:
EA00033DA2_1517.pdf
-
-
-
Special Documentation (SD)
Proline Promag 10 and 50 Supplementary information for Promag 10L and 50L, nominal diameters DN 1400 to 2400 (54
Electromagnetic flow measuring system
EN Select other language 01/12/2011Language:
English
Version:
01/12/2011
File size:
176.6 KB
File name:
SD00153DEN_0111.pdf
-
-
-
Special Documentation (SD)
Promag L Remote version IP67, type 6 enclosure – temporary use in water Special Documentation
Electromagnetic flowmeter
EN Select other language 19/11/2015Language:
English
Version:
19/11/2015
File size:
74.5 KB
File name:
SD01605DEN_0115.pdf
-
-
-
Special Documentation (SD)
SD Information on the Pressure Equipment Directive
Proline measuring instruments
EN Select other language 13/11/202402/05/201719/07/2016Language:
English
Version:
13/11/2024
File size:
286.4 KB
File name:
SD01614DEN_0424-00.pdf
-
-
-
Special Documentation (SD)
Proline Promag L Device-specific material load diagrams DN 300 (12") Special documentation
Electromagnetic flow measuring system
EN Select other language 01/03/2010Language:
English
Version:
01/03/2010
File size:
142.3 KB
File name:
SD143DA2_0310.pdf
-
-
-
Special Documentation (SD)
Proline Promag 10L, 50L, L 400/800 Supplementary documentation for the Operating Instructions Special Documentation
Electromagnetic flow measuring system
EN Select other language 25/02/2013Language:
English
Version:
25/02/2013
File size:
307 KB
File name:
SD01063DEN_0113.pdf
-
-
-
Special Documentation (SD)
Change of Directives Special Documentation
Change of Directives
EN Select other language 20/04/2016Language:
English
Version:
20/04/2016
File size:
52.2 KB
File name:
SD01764DEN_0116.pdf
-
-
-
Manufacturer Information (MI)
Proline Promag 10 Manufacturer information regarding software updates (NE 53)
New software version:
Promag 10 HART: 1.03.00EN Select other language 01/09/2009Language:
English
Version:
01/09/2009
File size:
145.2 KB
File name:
MI00037D_06_en_09.09.pdf
-
-
-
Case Study (CS)
Energieeffizienzoptimierung
Erfassung und Analyse des Heiz-
wärmebedarfs im Schulhaus
EttingenLanguage:
German
Version:
02/08/2021
File size:
935.6 KB
File name:
CS01710S_20_DE0120_Gemeinde_Ettingen.pdf
-
-
-
Case Study (CS)
Optimierung der Energieeffizienz
Erfassung und Analyse des Heizwärmebedarfs im Schulhaus Ettingen
Language:
German
Version:
24/02/2020
File size:
933.1 KB
File name:
CS01629S_20_DE0120_Gemeinde Ettingen.pdf
-