Specs at a glance
-
Accuracy
Standard 0.1%
Optional 0.075% -
Process temperature
-10°C...+100°C
(+14°F...+212°F) -
Pressure measuring range
100 mbar...10 bar
(1.5 psi...150 psi) -
Process pressure / max. overpressure limit
40 bar (600 psi)
-
Main wetted parts
Alloy C
316L -
Max. measurement distance
100 m (328 ft) H2O
-
Material process membrane
316L, AlloyC,
Gold-Rhodium -
Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
Field of application
The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.
For level and/or pressure measurement.
Process connections: Threads, flanges and hygienic connections
Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
Accuracy: ±0.075%
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Benefits
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation
Best batch-to-batch repeatability and long-term stability
Modular concept for easy replacement of display or electronics
HistoROM/M-DAT data backup for instrument settings and measured values
Function-monitored from the measuring cell to the electronics
Seamless and independent system integration (HART/PA/FF)
International usage thanks to a wide range of approvals
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Operating Instruction (BA)
Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA V04.01.zz
English version - 04/2017
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter Deltabar S FMD77, FMD78, PMD75 Differential pressure transmitter Deltapilot S FMB70 Hydrostatic pressure transmitter
EN 03/04/201710/12/201407/08/201301/10/201101/05/2010Language:
English
Version:
03/04/2017
File size:
4.8 MB
File name:
BA00296PEN_1616.pdf
-
-
-
Explosion Protection
Product family: Cerabar M, Cerabar S, Deltabar M, Deltabar S, Deltapilot M, Deltapilot S, Gammapilot, Gammapilot M, Levelflex, Liqui cap M, Liquiphant, Liquiphant FailSafe, Liquiphant M, Liquiphant S, Micropilot, Solicap M, Strahlenschutzbehälter, Strahler
German version - 10/2020
Product root: FMB50-, FMB51-, FMB52-, FMB53-, FMB70-, FMD77-, FMD78-, FMG50-, FMG60-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53- , FMP54-, FMP55-, FMP56-, FMP57-, FMR50-, FMR51-, FMR52-, FMR53-, FMR54-, FMR56-, FMR57-, FMR60-, FMR62-, FMR67-, FQG60-, FQG62-, FS G60-, FSG61-, FTI51-, FTI52-, FTI55-, FTI56-, FTL41-, FTL50-, FTL50H-, FTL51-, FTL51B-, FTL51C-, FTL51H-, FTL70-, FTL71-, FTL80-, FT L81-, FTL85-, PMC51-, PMC71-, PMD55-, PMD75-, PMP51-, PMP55-, PMP71-, PMP75- Region: Europe Approval agency: BV Protection: Ex i
Language:
German
Version:
20/10/2020
File size:
617.8 KB
File name:
EPS_15_ATEX_1_1011_X_R1.pdf
-
-
-
Technical Information (TI)
Deltapilot S FMB70
Hydrostatic level measurement
EN 27/09/202120/04/202001/03/201815/08/201601/09/2015Language:
English
Version:
27/09/2021
File size:
2.2 MB
File name:
TI00416PEN_2421.pdf
-
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN 06/12/202425/03/202415/09/202328/10/202130/07/2021Language:
English
Version:
06/12/2024
File size:
1.3 MB
File name:
TI00426FEN_2624.pdf
-
-
-
Operating Instruction (BA)
Deltapilot S FMB70 FOUNDATION Fieldbus (V04.00.zz) Operating Instructions
Pressure sensor with the CONTITE measuring cell
Condensate-resistant offering long-term stability; Communication
via FOUNDAT
ION FieldbusEN 01/08/202403/04/201710/12/201407/05/201423/05/2013Language:
English
Version:
01/08/2024
File size:
3.8 MB
File name:
BA00372PEN_1922-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA V04.01.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterEN 03/04/201710/12/201407/08/201301/10/201101/05/2010Language:
English
Version:
03/04/2017
File size:
4.8 MB
File name:
BA00296PEN_1616.pdf
-
-
-
Operating Instruction (BA)
Cerabar S / Deltabar S / Deltapilot S, Description of device functions FOUNDATION Fieldbus V 04.00.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterEN 03/04/201710/12/201407/05/201430/04/201301/10/2011Language:
English
Version:
03/04/2017
File size:
6.3 MB
File name:
BA00303PEN_1716.pdf
-
-
-
Operating Instruction (BA)
Deltapilot S FMB70 HART V02.30.zz Operating Instructions
Pressure sensor with CONTITE measuring cell
Condensate-proofedEN 01/08/202401/03/201810/12/201401/11/201408/05/2014Language:
English
Version:
01/08/2024
File size:
843.7 KB
File name:
BA00332PEN_2022-00 .pdf
-
-
-
Operating Instruction (BA)
Deltapilot S FMB70 PROFIBUS PA (V04.01.zz) Operating Instructions
Pressure sensor with the CONTITE measuring cell
Condensate-resistant offering long-term stability; Communication
via PROFIBU
S PAEN 01/08/202403/04/201710/12/201407/05/201407/08/2013Language:
English
Version:
01/08/2024
File size:
1.4 MB
File name:
BA00356PEN_1922-00.pdf
-
-
-
Operating Instruction (BA)
Cerabar S / Deltabar S / Deltapilot S HART V02.30.zz Description of Instrument Functions
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterEN 01/03/201810/12/201401/11/201407/05/201417/01/2013Language:
English
Version:
01/03/2018
File size:
4.8 MB
File name:
BA00274PEN_1816.pdf
-
-
-
Short Instruction (KA)
Exchange of sensor unit for separate version on Cerabar S PMP71 and Deltapilot S FMB70
Exchange of sensor unit for separate version on Cerabar S PMP71 and
Deltapilot S FMB70EN 24/04/2012Language:
English
Version:
24/04/2012
File size:
257.4 KB
File name:
KA00672PA2_0607.pdf
-
-
-
Short Instruction (KA)
Deltapilot S FMB70
Hydrostatic level measurement
EN 30/06/202203/04/201710/12/201407/05/201423/05/2013Language:
English
Version:
30/06/2022
File size:
1.2 MB
File name:
KA01026PEN_1821-00.pdf
-